Question/Answer

When preparing a sample for a total cyanide distillation, do you shake the sample prior to pouring off the 50 mL aliquot?

Samples should be homogenized prior to analysis.

What is the part number for your boiling tubes for the simple dist. (50 mL)

The part number you are looking for is C6010 - Borosilicate Glass Boiling Threaded Tube, 30X200mm.

What are the dimensions of this unit?

The manifold measures 19.5”w x 11.25”d x 25”h. The block will sit inside of the manifold footprint.

we do a 500 ml sample for raw influent ammonia would this work for that and how much is it

The SimpleDist System is designed for cyanide and ammonia distillations following any of the accepted EPA or Standard Methods methodologies. The system is designed to use either 50mL or 25mL of sample.

Can the traps be purchased without trapping solution?

The C6100 taps are always sold without any trapping solution. We offer the trapping solution in a \"Snip & Pour\" tube. Depending on the chemistry you are doing those tubes would be part # C7005 or C7125 for ammonia and C7115 for cyanide.

Can the traps be cleaned, refilled, and reused?

No - the traps are designed to be disposable and one-time use only.

is a vacuum pump included with the system?

A vacuum pump is not included with this system. If you need a vacuum source it must be ordered separately. Item G3050 is sufficient for this purpose.

Do you have a way to accurately measure the flow rate of the vacuum on each collection trap for cyanide distillation using the SimpleDist system?

We do not have any type of system designed to measure the vacuum in and out of the traps. The only guidance we have is to observe the bubbling rate inside the traps and keep them visually consistent.

Is the distillation method that you are using equivalent to any EPA methods/Standard Methods or approved?

Yes. We use a scaled version of the EPA methods for those included in the instruction manual. Standard Methods can be similarly scaled for any points in which the differ from the EPA methods to also be run on this unit.

what is the maximum weight of soil sample you can use in the simple Dist for Cyanide?

Our procedure is based off of EPA accepted methods that call for the use of 0.5-1.0 g of solid material that is distilled into 50 mL of catch solution. The amount of cyanide and organic materials present in the sample will be the ultimate determination in how much sample can be used. Generally samples should contain less than 2500 ug of cyanide (to ensure proper trapping in the distillate) and be low in organic components. There is no numerical value to determine if the sample will distill properly but the more organic constituents are present the more likely the sample is to boil over and/or cake the bottom of the frit and interrupt the distillation procedure.

Can TKN analysis be done on this?

This block is not capable of reaching the temperature necessary to perform TKN digestion. However, the system can distill the digestate the results from TKN digestion if your process requires it

Traps disposable? Hotblock used for digestion, too?

Any sized HotBlock can be used with the SimpleDist system. The Block included in this is a 12 place block but the manifold will fit on any of our standard Blocks. If you already have one you can easily get just the manifold and glassware to use the block for distillation. The traps are disposable.

Is this approved for sm 4500 cn?

Different pieces of equipment are no longer receiving approval for various methods. Instead the EPA has issued a statement that only methods are approved. As long as the equipment can be used following the approved method it will be acceptable. This distillation system follows the exact same chemistry as is found in all approved cyanide methods.